1. Elevator maintenance personnel must hold the low-voltage maintenance "electrician operation certificate" and "elevator maintenance work operation certificate" issued by the authority of the region.
2. When the elevator is being repaired and maintained, it must be no less than two people; it must be done strictly in accordance with the safe operating procedures during work, and it is strictly forbidden to operate after drinking; it is not allowed to chat at work; it is not allowed to short the broken door lock with wires. switch.
3. Before you work, you should check your labor insurance supplies and carrying tools for problems. If you have no problems, you can wear them and carry them.
4. When the elevator is being repaired and maintained, it is generally not allowed to be charged. If it is necessary to have live working, there should be a guardian and reliable safety measures.
5. When the elevator is under maintenance, it is absolutely not allowed to carry passengers or load goods.
6. Proficiency in the correct and safe use of the tools commonly used in this type of work, as well as safety regulations for lifting and dismounting.
7. Must be proficient in the first-aid method of electric shock, master fire prevention knowledge and common knowledge of fire fighting, and master the method of rescued trapped passengers when the elevator fails and stops.
8. It is necessary to grasp the handling procedures after the accident.
(2) Safety preparation before maintenance work
1. The "check-out" sign should be placed in the car or in the obvious area of ​​the population.
2. Let the unrelated person leave the car or other maintenance work site, close the door, and when the door cannot be closed, use the appropriate grille to block the population to prevent unrelated personnel from entering the elevator.
3. When repairing electrical equipment, generally turn off the power or take appropriate safety measures.
4. When a person is doing maintenance work on the car top, he must press the emergency stop button on the car top inspection box, or pull the safety pliers linkage switch, close the door, and hang the "person in the car top" on the control box. , not allowed to tamper with the signs.
5. Enter the pit and open the low-voltage lighting in the pit first, then press the pit stop switch to cut off the elevator circuit so that the car can no longer run. And put warning signs on the landings and landing doors and car doors.
(3) Safety regulations during maintenance operations
1. When the rotating part is filled, cleaned, or the wire rope is worn, the elevator must be stopped.
2. When a person works on the car top, there should be a choice of standing, no dirt under the feet, otherwise it should be cleaned to prevent slipping.
3. When the person prepares to start the elevator on the car top to observe the working condition of the elevator components, he must firmly hold the car rope head board; the car frame upper beam or the protective fence and other parts. Do not hold the wire rope and note that the entire body is placed within the size of the car frame to prevent it from being injured by other parts. When the driver or maintenance personnel in the car need to open the elevator, it is necessary to explain and cooperate, and it is not allowed to start the elevator without permission.
4. In the case where multiple elevators share a single hoistway, the elevator should be carefully watched. In addition to paying attention to the situation of the elevator, attention should also be paid to the dynamics of other elevators to prevent them from colliding.
5. It is forbidden to smoke in the hoistway and on the car top.
6. When repairing electrical components, it should be avoided as much as possible. It must be energized or difficult to operate when the power is completely cut off. It should be protected against electric shock, and there should be coordination between the host and the assistant. Pay attention to the sudden start of the elevator.
7. The hand lamp used must be a safety light with a shield and a voltage of 36V or less.
8. It is strictly forbidden for the maintenance personnel to stand in the hoistway outside the hoistway, and the two feet stand between the top of the car and the sill of the landing door, or the long-term maintenance operation between the sill of the landing door and the pedal of the car.
9. After entering the pit, the emergency stop switch on the light barrier light box or the disconnection switch of the speed limit tensioning device should be disconnected.
10. The following safety measures should be taken when the maintenance work gap needs to leave the site temporarily.
(1) Close the doors of each floor (hall). If you can't close it, you must set obvious obstacles and hang the "dangerous" and "never close" warning signs at the door.
(2) Cut off the main power switch.
(3) Cut off heat sources such as blowtorch, soldering iron, electric welder and glare.
(4) A special person should be on duty if necessary.
11. When the maintenance work is over, the following work should be done:
(1) Collect inventory tool materials, clean and clean the work site, and remove warning signs and billboards.
(2) Return all the switches to their original positions, and test run, check that the various mechanisms, electrical, etc. are intact.
(3) Fill in the maintenance record.
(4) Delivery of the repaired elevator to the acceptance.
(4) Safety operation regulations for maintenance personnel when repairing the main parts of the elevator
1. Safety regulations during maintenance of the machine room:
(1) It is strictly forbidden to carry out maintenance when the traction machine is running.
(2) When repairing electrical equipment and wiring, it must be carried out with the power supply disconnected; when working with live power, it must be operated in accordance with the safety regulations for live operation; the grounding device is good.
(3) When adjusting the brake, it is forbidden to loosen the brake spring (main spring of the brake); if it is necessary to release the brake, there must be measures to prevent the rolling.
(4) The engine room maintenance day, the elevator driver or maintenance personnel must be left in the car; when the car is operated in the machine room, only the inspection speed is allowed, and the person in the car or on the top of the car must be contacted. Well, the car can be driven after the car door and the landing door are closed; it is strictly forbidden to start the car with the floor door open.
(5) When it is necessary to manually shake the traction machine, the power must be disconnected first. Before shaking, be sure to contact the people on the top of the car and in the car. In order to prevent the car from accidentally rolling when the brake is opened, the maintenance personnel who operate the brake should work intermittently and prepare for the brake holding brake at any time. For elevators without a reducer, it is not suitable for maintenance by means of a hand-slewing motor.
2. Safety regulations for maintenance on the roof of the car:
(1) Non-maintenance personnel are strictly prohibited from entering the top of the car. Before entering the car roof, you must know the exact location of the car. Before opening the landing door to enter the top of the car, you must see the location of the car, see the surrounding environment, and ensure that there are no people at the landing door. When there is absolutely no problem with safety, you can enter the top of the car. Immediately after entering the top of the car, close the landing door to prevent others from entering.
(2) When entering the top of the car, first cut off the emergency stop switch (button) on the service box on the top of the car, so that the elevator can not run, and then put the relevant switch into the inspection state.
(3) The maintenance personnel on the top of the car should generally not exceed three people, and there is a special person responsible for operating the elevator. Before starting, you should remind all the people on the top of the car to pay attention to safety, and check that there is no problem before you can check the speed operation. The person on the top of the car when driving is not allowed to poke any part of the body out of the fence.
Pay attention to safety when checking on the car top, and concentrate on standing and standing. When performing various tasks, the maintenance switch on the car top should be cut off to make the car inoperable. Only when the car top maintenance personnel thinks that the car needs to be lifted, can he issue a command and turn on the maintenance switch to make the car run. . It should be noted that when the leveling plate has been inserted into the sensor, although the elevator running button is not pressed, as long as the circuit elevator car is automatically leveled, the car top personnel must check the level before turning on the service switch. Whether the layer shielding plate has been inserted into the inductive spring sensor, it is expected that the possible action and the safe positioning position can be safe.
(4) During maintenance, it is strictly forbidden to operate between the car and the landing door. Smoking is strictly prohibited on the car top.
(5) When leaving the top of the car, the function switches on the car top operation box should be reset, and spare parts, tools and sundries are not allowed to be stored on the car top. Leave after ensuring that the landing door is closed.
3. Safety regulations for maintenance in the car:
(1) Before entering the car, the exact position of the car should be confirmed first. It must not be judged only by the number of layers indicated by the floor indicator.
(2) After entering the car, check whether the function buttons on the control box are flexible and reliable, and no smoking is allowed in the car.
(3) When maintenance and maintenance of the elevator, it is strictly forbidden to open the door and drive. When the landing door is faulty and cannot be closed temporarily, it is necessary to hang warning signs, equipment fences, and send special personnel to monitor.
(4) When working in the car, it is strictly forbidden to exceed any part of the body to prevent crushing.
(5) When leaving the car, the car door and the landing door should be closed and locked before leaving.
4. Safety regulations for maintenance in the pit:
(1) First cut off the emergency stop switch or power supply of the elevator, and then work in the pit.
(2) Use a ladder when laying the pit. The ladder should be strong and placed reasonably and smoothly. It is strictly forbidden to smoke in the pit.
(3) When working in the pit, when driving, the maintenance personnel must pay attention to whether the position is safe, prevent being caught by the line, the balance chain, or other accidents.
(4) There must be low-voltage lighting in the pit, and the brightness is sufficient to meet the working requirements.
(5) When working in the pit, pay attention to the surrounding environment to prevent the device from being damaged by the device in the pit.
(6) When working in the pit, the engine room and the car roof must not be repaired at the same time to prevent accidents.
(5) Safety regulations for the use of elevators during maintenance
1. When the elevator is being repaired or the test is being repaired regularly, the main power supply must be disconnected. The elevator car can not carry passengers or load goods. At the same time, it should be suspended at the door level, the car inner control box, the machine room control cabinet, etc., and the contents of “checking and disabling”, “not allowed to close”, “repairing, not being able to start”, etc. The warning sign shall be directed by a special person during the test run. According to the instructions issued by the commander, the warning sign or the elevator can be removed.
2. When the elevator is inspected, tested, repaired, or cleaned, the power switch of the equipment room should be disconnected to ensure safety.
3. When the elevator is inspected and repaired, a safe voltage of 36V or less must be used. For this purpose, the elevator machine room, the pit of the hoistway, the car roof or the car floor should be equipped with low-voltage power sockets for maintenance.
4. The metal casing of all electrical equipment of the elevator should have a good grounding:
(1) Electrical equipment, cabinets, screens, boxes, boxes, slots, and bamboos should have no easily identifiable grounding ends.
(2) According to the color of the ground wire, it is a yellow-green two-color insulated wire.
(3) The neutral and ground wires should always be separated. (Except for elevator electrical systems controlled by relays).

Bluetooth Earphone

1.There is no wire, it is very convenient to use;
2. Its radiation is a few tenths of that of a mobile phone, which is basically negligible, and it is a green and healthy product;
3. The appearance is cool, can show the personality, catch up with the fashion

Bluetooth; Earphone;Earbuds

Shenzhen Linx Technology Co., Ltd. , https://www.linxheadphone.com

This entry was posted in on