Model NO.: WSP-NED/T
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Protection: Short Circuit / Overload / Over Voltage
Model NO.: WSP-NED/T
Modulation System: PWM
In-Out: Lifting Pressure Type
Power Supply Voltage: 1.5-36V
Pack Sealing Size: SC-70
Brand: OEM
Protection: Short Circuit / Overload / Over Voltage
 25W-150W Single output switching power supply(NED/T Series), power LEDFeatures:
*Universal AC input / full range (NES/D-100,NES-150 AC input selectable by Switch)
*Protections:Short circuit / Overload / Over voltage
*Built-in over temperature protection for NES-15
*Cooling by free air convection
*Small size, high power density
*Low size, high reliability
*100% full load burn-in test
*Most economical low wattage solution with safety certificates
*2 years warranty
Series No. | Model No. | Specification | ||||||||||||||
AC input range | AC inrush Current(Max.) | DC adjustable range | Overload protection | Over voltage protection | Withstand Voltage | Safety standards | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | MAXÂ | Size(mm) | ||
NED-35 | NED-35A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
by potentiometer for single output 10% | 110%~150% hiccup mode, auto-recovery | 115%~135% rated output voltage,shut off | I/P-O/P:3KVAC,I/P-FG:2KVAC, O/P-FG:0.5KVAC.1minute | UL60950-1,EN60950-1(NES-150 only),GB4943(NES only),EN60950-1 | EN55022 class B,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254(NES only) | Terminal Block for input and output | 5V,0.5~5A | ±2% | 80mV | 78.0% | 32W | 99x97x36 |
12V,0.1~1.5A | ±6% | 120mV | ||||||||||||||
NED-35B | 5V, 0.5~4A | ±2% | 80mV | 78.0% | 35W | 99x97x36 | ||||||||||
24V,0.2~1.3A | ±6% | 200mV | ||||||||||||||
NED-50 | NED-50A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
5V,1~6A | ±2% | 80mV | 79.0% | 54W | 99x97x36 | |||||||
12V,0.3~3A | ±6% | 120mV | ||||||||||||||
NED-50B | 5V,1~6A | ±2% | 80mV | 82.0% | 54W | 99x97x36 | ||||||||||
24V,0.2~2A | ±6% | 200mV | ||||||||||||||
NED-75 | NED-75A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
5V,1~8A | ±2% | 80mV | 78.0% | 71W | 159x97x38 | |||||||
12V,0.3~4A | ±6% | 120mV | ||||||||||||||
NED-75B | 5V,1~6A | ±2% | 80mV | 81.0% | 73W | 159x97x38 | ||||||||||
24V,0.2~3A | ±6% | 200mV | ||||||||||||||
NED-100 | NED-100A | 115/230VAC | Cold start, 45A/230VAC |
-5%~+10%(NES-100/150); CH1~5%~+10%(NES-100) |
115%~135% hiccup mode, auto-recovery | I/P-O/P:3KVAC,I/P-FG:2KVAC, O/P-FG:0.5KVAC.1minute | UL60950-1,EN60950-1(NES-150 only),GB4943(NES only),EN60950-1 | EN55022 class B,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254(NES only) | Terminal block for input and output | 5V,2~10A | ±2% | 80mV | 80.0% | 100W | 199x98x38 | |
12V,0.7~7A | ±10% | 120mV | ||||||||||||||
NED-100B | 5V,1~10A | ±2% | 80mV | 82.0% | 100W | 199x98x38 | ||||||||||
24V,0.3~3.5A | ±8% | 200mV | ||||||||||||||
NED-100C | 12V,0~8A | ±2% | 120mV | 80.0% | 99W | 199x98x38 | ||||||||||
5V,0~3A | ±3% | 80mV | ||||||||||||||
NED-100D | 24V,0~4A | ±2% | 120mV | 82.0% | 99W | 199x98x38 | ||||||||||
5V,0~3A | ±3% | 80mV | ||||||||||||||
NET-35 | NET-35A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
by potentiometer for single output 10% | 115%~135% rated output voltage,shut off | 5V,0.5~4A | ±2% | 80mV | 78.0% | 30W | 99x97x36 | |||||
12V,0.1~1.5A | ±6% | 120mV | ||||||||||||||
-5V,0.1~0.5A | ±6% | 120mV | ||||||||||||||
NET-35B | 5V,0.5~4A | ±2% | 80mV | 82.0% | 100W | 99x97x36 | ||||||||||
12V,0.1~0.5A | ±6% | 120mV | ||||||||||||||
-12V,0.1~0.5A | ±6% | 120mV | ||||||||||||||
NET-35C | 5V,0.5~3.5A | ±2% | 80mV | 79.0% | 35W | 99x97x36 | ||||||||||
15V,0.1~1.5A | ±8% | 150mV | ||||||||||||||
-15V,0.1~0.5A | ±8% | 150mV | ||||||||||||||
NET-35D | 5V,0.5~3.5A | ±2% | 120mV | 79.0% | 37W | 99x97x36 | ||||||||||
24V,0.1~1A | ±8% | 200mV | ||||||||||||||
12V,0.1~1A | ±8% | 120mV | ||||||||||||||
NET-50 | NET-50A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
I/P-O/P:3KVAC,I/P-FG:2KVAC, O/P-FG:0.5KVAC.1minute | UL60950-1,EN60950-1(NES-150 only),GB4943(NES only),EN60950-1 | EN55022 class B,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254(NES only) | Terminal block for input and output | 5V,0.5~5A | ±2% | 80mV | 76.0% | 47W | 129x98x38 | |||
12V,0.2~2.5A | ±6% | 120mV | ||||||||||||||
-5V,0.1~0.7A | ±5% | 120mV | ||||||||||||||
NET-50B | 5V,0.6~5A | ±2% | 80mV | 78.0% | 50W | 129x98x38 | ||||||||||
12V,0.2~2.5A | ±6% | 120mV | ||||||||||||||
-12V,0.1~0.7A | ±5% | 120mV | ||||||||||||||
NET-50C | 5V,0.6~5A | ±2% | 80mV | 78.0% | 50W | 129x98x38 | ||||||||||
15V,0.1~2A | ±8% | 150mV | ||||||||||||||
-15V,0.1~0.7A | ±5% | 150mV | ||||||||||||||
NET-50D | 5V,0.6~5A | ±2% | 120mV | 80.0% | 51W | 129x98x38 | ||||||||||
24V,0.1~1.5A | ±8% | 200mV | ||||||||||||||
12V,0.1~1.5A | ±6% | 120mV | ||||||||||||||
NET-75 | NET-75A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
5V,0.6~7A | ±2% | 80mV | 76.0% | 47W | 129x98x38 | |||||||
12V,0.2~3.5A | ±6% | 120mV | ||||||||||||||
-5V,0.1~0.7A | ±5% | 120mV | ||||||||||||||
NET-75B | 5V,0.6~7A | ±2% | 80mV | 78.0% | 50W | 129x98x38 | ||||||||||
12V,0.2~3.5A | ±6% | 120mV | ||||||||||||||
-12V,0.1~0.7A | ±5% | 120mV | ||||||||||||||
NET-75C | 5V,0.6~5A | ±2% | 80mV | 78.0% | 50W | 129x98x38 | ||||||||||
15V,0.1~2A | ±8% | 150mV | ||||||||||||||
-15V,0.1~0.7A | ±5% | 150mV | ||||||||||||||
NET-75D | 5V,0.6~5A | ±2% | 120mV | 80.0% | 51W | 129x98x38 | ||||||||||
24V,0.1~1.5A | ±8% | 200mV | ||||||||||||||
12V,0.1~1.5A | ±6% | 120mV |
Features:
*Universal AC input / full range (NES/D-100,NES-150 AC input selectable by switch)
*Protections:Short circuit / Overload / Over voltage
*Built-in over temperature protection for NES-15
*Cooling by free air convection
*Small size, high power density
*Low size, high reliability
*100% full load burn-in test
*Most economical low wattage solution with safety certificates
*2 years warranty
Series No. | Model No. | Specification | ||||||||||||||
AC input range | AC inrush Current(Max.) | DC adjustable range | Overload protection | Over voltage protection | Withstand Voltage | Safety standards | EMC standards | Connector input/output |
Output | Voltage tolerance | Ripple&noise | Efficiency | MAXÂ | Size(mm) | ||
NED-35 | NED-35A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
by potentiometer for single output 10% | 110%~150% hiccup mode, auto-recovery | 115%~135% rated output voltage,shut off | I/P-O/P:3KVAC,I/P-FG:2KVAC, O/P-FG:0.5KVAC.1minute | UL60950-1,EN60950-1(NES-150 only),GB4943(NES only),EN60950-1 | EN55022 class B,EN61000-3-2,3,EN61000-4-2,3,4,5,6,8,11,GB9254(NES only) | Terminal block for input and output | 5V,0.5~5A | ±2% | 80mV | 78.0% | 32W | 99x97x36 |
12V,0.1~1.5A | ±6% | 120mV | ||||||||||||||
NED-35B | 5V, 0.5~4A | ±2% | 80mV | 78.0% | 35W | 99x97x36 | ||||||||||
24V,0.2~1.3A | ±6% | 200mV | ||||||||||||||
NED-50 | NED-50A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
5V,1~6A | ±2% | 80mV | 79.0% | 54W | 99x97x36 | |||||||
12V,0.3~3A | ±6% | 120mV | ||||||||||||||
NED-50B | 5V,1~6A | ±2% | 80mV | 82.0% | 54W | 99x97x36 | ||||||||||
24V,0.2~2A | ±6% | 200mV | ||||||||||||||
NED-75 | NED-75A | 85~264VAC;120~370VDC | Cold start, 45A/230VAC |
5V,1~8A | ±2% | 80mV | 78.0% | 71W | 159x97x38 | |||||||
12V,0.3~4A | ±6% | 120mV | ||||||||||||||
NED-75B | 5V,1~6A | ±2% | 80mV | 81.0% | 73W | 159x97x38 | ||||||||||
24V,0.2~3A | ±6% | 200mV | ||||||||||||||
NED-100 | NED-100A | 115/230VAC | Cold s Military Reliable Fuse,250 AMPS Military Fuse,Military High-Reliability Fuse Tengqiang Electronics Co.Ltd , http://www.xingdaele.com |